Temperature Calibration
Home

Blog

Blog

  • The Science and Technology of Temperature Measurement: From Traditional to Smart Mar 29, 2025
    Temperature measurement is essential in scientific research and industrial production. It ensures accuracy in laboratories, stabilizes production processes, and enhances smart home and healthcare applications. However, it involves complex sensor technologies, data processing, and precise instrument design. Modern technology continues to improve temperature measurement through high-precision instruments.   Basic Principles of Temperature Measurement Temperature measurement is based on physical property changes of substances at different temperatures. Key principles include Thermal Expansion, Electrical Resistance, Thermoelectric Effect, and Blackbody Radiation. Among them, sensor technology plays a critical role. Common temperature sensors include Thermistors, Resistance Temperature Detectors (RTD), and Thermocouples.   Thermistors Thermistors, made from semiconductor materials, exhibit resistance changes with temperature. Based on their temperature coefficients, they are classified into Positive Temperature Coefficient (PTC) and Negative Temperature Coefficient (NTC) thermistors. These sensors offer high sensitivity, small size, and rapid response, making them ideal for precision measurement applications.   Resistance Temperature Detector (RTD) RTDs, particularly platinum resistance sensors, measure temperature based on changes in electrical resistance. Their excellent accuracy, stability, and anti-interference capabilities make them widely used in industrial automation and environmental monitoring. As a reliable industrial thermometer, RTDs provide precise data for production control and efficiency optimization.   Thermocouples Thermocouples generate a thermoelectric potential based on the Seebeck effect. As a widely used contact thermometer, they are essential for applications requiring high-temperature monitoring, such as steel metallurgy and petrochemical industries. Their simple structure, durability, and fast response time make them ideal for harsh environments.   Advancements in Temperature Measurement Technology Modern temperature measuring instruments have significantly improved in accuracy, portability, and intelligent functionality.     High-Precision Measurement Advanced sensor technology and signal processing algorithms have greatly enhanced measurement precision. Some precision thermometers achieve accuracies of ±0.02℃, making them suitable for stringent research and industrial applications. Precision thermometers can detect even the smallest temperature variations, ensuring reliable data for critical processes.   Portability and Integration The development of compact, lightweight thermometers has made field measurements more efficient. Handheld precision thermometers offer convenience for mobile detection, emergency response, and industrial applications. Their quick deployment in critical environments, such as cold chain logistics, ensures accurate temperature tracking.   Intelligent Data Management With the integration of IoT, cloud computing, and big data, modern thermometers now support wireless connectivity. Industrial thermometers can transmit real-time temperature data for automated monitoring and process optimization. Smart data management features simplify trend analysis, report generation, and remote monitoring.   Conclusion Temperature measurement continues to evolve with technological advancements, improving accuracy and efficiency across various industries. Whether for research, industrial automation, or environmental monitoring, selecting the right temperature measurement device is crucial.   For high-performance temperature solutions, ZHICE-ELEC offers a range of precision thermometers, industrial thermometers, and contact thermometers designed for diverse applications. Visit ZHICE-ELEC's official website to explore cutting-edge temperature measurement technology.
  • What's the Difference Between PT100 and PT1000 Sensors? Dec 18, 2024
    When it comes to temperature measurement, choosing the right sensor can make a significant difference in accuracy and performance. PT100 and PT1000 temperature sensors are two of the most commonly used platinum resistance thermometers (PRTs) in industrial and laboratory settings. While they may appear similar at first glance, understanding their differences is crucial for selecting the right sensor for your application. This article delves into their key distinctions, helping you make an informed decision.   What Are PT100 and PT1000 Sensors? Both PT100 and PT1000 temperature sensors belong to the platinum resistance thermometer family. These sensors rely on the predictable change in electrical resistance of platinum with temperature. Platinum is preferred due to its stability, repeatability, and high-temperature range, making it ideal for precision temperature measurements. - PT100: The "100" in PT100 indicates that the sensor’s resistance is 100 ohms at 0°C. - PT1000: Similarly, PT1000 has a resistance of 1000 ohms at 0°C. The difference in their resistance values plays a significant role in their performance, cost, and application suitability.     Key Differences Between PT100 and PT1000 1. Resistance Value and Signal Strength - PT100 temperature sensors have lower resistance (100 ohms at 0°C), which results in a smaller voltage signal. - PT1000 temperature sensors have a higher resistance (1000 ohms at 0°C), offering a stronger signal and better immunity to electrical noise.   Key takeaway: PT1000 temperature probes are better suited for environments with long cable runs or high electromagnetic interference.   2. Accuracy and Sensitivity - Both PT100 and PT1000 sensors offer high accuracy and sensitivity. However, the smaller signal of PT100 sensors makes them more susceptible to errors from lead wire resistance. - PT1000’s higher resistance minimizes the impact of lead wire resistance, enhancing accuracy over long distances.   Key takeaway: PT1000 sensors often provide greater accuracy in installations requiring extended cabling.   3. Cost - PT100 sensors are typically more cost-effective than PT1000 sensors due to their lower material usage.   Key takeaway: For budget-conscious projects, PT100 sensors may be the preferred choice if noise immunity and cable length are not concerns.   4. Application Suitability - PT100 sensors are widely used in industrial applications requiring robust and reliable temperature measurements. - PT1000 sensors excel in HVAC systems, environmental monitoring, and applications where signal integrity over long distances is crucial.   So, which Sensor Should You Choose? The choice between PT100 and PT1000 depends on your specific requirements: PT100: Ideal for industrial processes and applications with shorter cable runs. PT1000: Best for environments with long cable distances or high electrical noise.   Why Choose ZHICE-ELEC for Your Temperature Sensors? At ZHICE-ELEC, we specialize in high-precision temperature sensors, including PT100 and PT1000 models. With a commitment to quality and innovation, our products are designed to meet the demanding needs of industrial and scientific applications. Explore our temperature sensor solutions and discover why customers worldwide trust us for their temperature measurement needs.   Conclusion Understanding the differences between PT100 and PT1000 temperature sensors is essential for making the right choice. Factors such as resistance, signal strength, accuracy, and application needs play a pivotal role in determining the most suitable option. Whether you need a PT100 sensor for industrial use or a PT1000 sensor for environmental monitoring, ZHICE-ELEC offers reliable and precise solutions tailored to your requirements.   Top Temperature Sensor Keywords: temperature sensor, platinum resistance thermometer, PT100 sensor, PT1000 sensor, industrial temperature measurement.  
  • Environmental Monitoring: Challenges and Requirements for Temperature and Humidity Control Nov 25, 2024
    Maintaining consistent temperature and humidity levels is a cornerstone of quality assurance in industries such as manufacturing, research, and storage. These environmental factors, while often overlooked, can have far-reaching impacts on production outcomes, product longevity, and experimental accuracy. Advanced tools like temperature and humidity loggers, or sometimes with wireless data transferring functions like wireless data loggers have become indispensable for meeting the challenges of environmental monitoring in these contexts. Effective environmental monitoring is not without its challenges. Addressing these requires not just the right tools but a deep understanding of the demands imposed by various applications.   Why Temperature and Humidity Monitoring Is Crucial? Temperature and humidity are more than mere environmental parameters—they are critical factors influencing materials, processes, and the stability of products.   -Production Environments: In pharmaceuticals and food processing, maintaining specific conditions is necessary to prevent contamination and ensure compliance with safety standards. Temperature and humidity loggers are critical for tracking these parameters throughout production. In electronics, uncontrolled humidity can lead to condensation, corrosion, or electrostatic discharge, potentially damaging components. A reliable wireless data logger can provide real-time insights, enabling quick responses to changes.   -Research and Laboratories: Experimental accuracy depends on stable environmental conditions. Variations in humidity or temperature can compromise results or invalidate data. Data loggers ensure these parameters are documented precisely, supporting reproducibility and compliance. Sensitive equipment like microscopes or spectrometers often requires controlled surroundings to operate optimally.   -Storage and warehouse temperature humidity monitoring: Products like vaccines, chemicals, and perishable foods are highly sensitive to environmental changes. Deviation from prescribed conditions can lead to spoilage, reduced efficacy, or outright waste. Wireless data loggers allow remote monitoring and real-time alerts for these critical storage environments.   Challenges in Temperature and Humidity Monitoring 1. Dynamic Environmental Factors Fluctuations in weather, seasonal variations, and HVAC system inconsistencies can make it challenging to maintain a steady environment. Without constant monitoring, these changes can go unnoticed until they cause significant issues.   2. Large-Scale Facilities Monitoring temperature and humidity across expansive areas like warehouses or production floors requires systems capable of covering wide spaces. Variability across different sections of a facility adds complexity.   3. Compliance with Regulations Industries like pharmaceuticals and food production are governed by strict regulations that demand detailed records of environmental conditions. Failing to meet these standards can result in penalties, product recalls, or damage to reputation.   4. Data Management and Analysis Collecting data is only part of the solution. Interpreting trends, identifying risks, and maintaining compliance records can overwhelm manual processes, necessitating automated solutions.   5. Real-Time Alerts and Rapid Response Quick detection and response are essential to prevent losses. For example, a sudden spike in temperature during vaccine storage could render the entire batch unusable. Real-time alerts and immediate action plans are critical.     Requirements for Effective Environmental Monitoring To address these challenges, temperature and humidity monitoring systems must meet several essential requirements:   1. High Accuracy and Reliability Precision in measurement is non-negotiable. Even small inaccuracies can have significant consequences, particularly in regulated environments. Sensors and loggers must deliver consistent and trustworthy readings.   2. Comprehensive Coverage For large facilities, systems need to monitor conditions across multiple zones. Wireless or networked solutions can bridge gaps and provide a holistic view of environmental conditions.   3. Ease of Use User-friendly interfaces, intuitive setup, and accessible data management tools are vital for ensuring staff can operate the system effectively without extensive training.   4. Scalability Monitoring needs often grow over time, whether due to expanded facilities, increased production, or stricter compliance requirements. Systems must be able to scale seamlessly to meet future demands.   5. Compliance Support Devices and systems should align with industry standards, such as ISO 17025 or FDA regulations, and facilitate easy reporting for audits or inspections.   6. Durability In environmental monitoring, durability often hinges on the battery life of data loggers and sensors. Devices deployed in remote or hard-to-access areas, such as high-storage shelves, laboratory chambers, or expansive production floors, must operate autonomously for extended periods. Frequent battery replacements can disrupt operations, increase maintenance costs, and compromise data continuity. Advanced wireless data monitoring systems also integrate power-saving modes and battery health indicators, further improving their durability and effectiveness in demanding applications.   7. Data Integration and Automation Modern monitoring systems should integrate with existing workflows and automation platforms, providing actionable insights, trend analysis, and real-time notifications when thresholds are exceeded.   Striking the Balance Implementing an effective temperature and humidity monitoring system is not just about meeting current needs but also anticipating future challenges. Businesses must strike a balance between upfront costs, system capabilities, and long-term benefits, ensuring that their chosen solutions align with operational goals and industry demands. By addressing the inherent challenges and adhering to rigorous requirements, organizations can ensure optimal environmental control, protect their investments, and maintain compliance with regulatory standards.
  • Pure Steam Quality Tests: necessity for testing, reasons for failure and solutions Oct 08, 2024
    When pure steam from the water system is used for moist heat sterilization, in order to ensure the sterilization effect, the pharmaceutical industry must regularly conduct three important tests on pure steam related to sterilization quality: non-condensable gas content, superheat and dryness. The standard for clean steam is dryness above 95%, condensed water meets EN285 requirements, non-condensable gas below 3.5% (specific data will vary from company to company), and the quality of pure steam condensate must meet the standards for water for injection.   Why is it necessary to test the quality of pure steam? The logarithmic model of saturated steam sterilization assumes that there are no non-condensable gases and overheating in the saturated steam. Wet steam, superheated steam, and steam containing non-condensable gases can potentially have adverse effects on the sterilization rate of porous/solid items in the process.   1)Necessity of Dryness Testing: The dryness of steam is calculated by measuring the relationship between the temperature change of a known amount of water and the amount of steam required to cause that temperature change. Ideally, the temperature increase is directly proportional to the amount of steam delivered to heat the water, resulting in a dryness value of 1.0, which means completely dry steam without liquid water. If the dryness is 0, it indicates 100% water. Typically, the dryness value is less than 1.0 because there is heat loss in well-insulated piping systems. Since the dryness value at the chamber inlet may be much lower than the dryness value inside the sterilizer, it is important to measure steam dryness at both locations. The acceptance criterion for clean steam dryness (the fraction of steam relative to water - 1.0 = all steam, no water) should be at least 0.95, or 95% by weight. For laboratory autoclaves, a dryness as low as 90% is considered acceptable, however, steam with a value below this is considered wet steam. During routine steam sterilization processes, we do not want to use wet steam because it cannot deliver as much energy to the load as saturated steam and can lead to what is known as "wet packs." The presence of moisture can adversely affect bacterial retention performance. The purpose of dryness testing is to remove droplets from packaging materials to ensure sterilization efficiency.   2)Necessity of Non-condensable Gas Testing: Non-condensable gases (NCG) refer to gases that do not liquefy during the saturated steam sterilization process, typically air. Compared to steam, air is a poor sterilizing agent. For example, a typical dry heat sterilization exposure phase lasts for more than two hours at a temperature of at least 160°C/320°F. Steam sterilization usually exposes for 15 minutes at 121°C/250°F or for 3.5 minutes at 134°C, and the difference in efficacy is evident. In short, non-condensable gases reduce the effectiveness of sterilization. The percentage of non-condensable gases in steam should be less than or equal to 3.5% (by volume).   3)Necessity of Superheat Value Testing: Superheated steam refers to steam that has a temperature value above the boiling point temperature at a certain pressure. When the temperature and moisture content do not match, two situations may occur: 1) If the moisture content is higher than the temperature saturation, a wet load will occur, as described earlier. 2) When the moisture content is lower than the temperature saturation, this condition is called superheat. In a superheated condition, the steam is too dry, and its energy is too high. When the steam condenses on the load, the energy released is sufficient to melt plastic packaging or char paper packaging. Therefore, we test the superheat value of steam to avoid this situation.     Analysis of Non-compliance and Solutions 1.Non-condensable gas non-compliance may be caused by: 1) Fluctuations in Steam Pressure Explanation: Fluctuations in steam pressure may originate from an unstable steam source, poor piping design, or imprecise control systems. These fluctuations can affect the gas composition in the steam, especially when the pressure suddenly drops, causing the gases dissolved in the steam to precipitate, increasing the content of non-condensable gases. Solutions: In addition to testing when the steam system is unloaded, check the stability of the steam source, optimize the piping design to reduce pressure fluctuations, and ensure the accuracy of the control system.   2) Short Operating Time of the Steam System Explanation: A newly started or short-time operated steam system may not have reached a stable state, and the impurities and gas composition in the steam may not have been completely eliminated. Solutions: Ensure that the steam system has sufficient preheating and operating time to reach a stable state before testing.   3)  Inherent Issues with Steam Quality Explanation: The pure steam generator may have malfunctions or improper settings, resulting in steam containing excessive non-condensable gases. Measures: Contact the equipment supplier for professional tuning and maintenance to ensure the normal operation of the pure steam generator and the quality of the steam.   2.Superheat non-compliance may be caused by: Explanation: Superheat is usually not a problem, but if there is overheating or uneven cooling in the steam/water system, it may affect the measurement results of superheat. Solutions: Check whether the heating and cooling equipment of the steam system is operating normally to ensure that the temperature of the steam is stable during transmission.   3.Dryness value non-compliance may be caused by: 1) Absence of Drain Valves in Steam Pipelines: Explanation: The role of drain valves is to promptly remove condensate from steam pipelines to prevent accumulation. If not installed or if the drain valve is faulty, condensate will accumulate in the pipeline, affecting the dryness of the steam. Solutions: Install and regularly check the working condition of the drain valves to ensure their normal operation.   2) Testing Operation Issues: Explanation: Improper operations before testing, such as not fully venting air and condensate from the steam pipeline, can lead to inaccurate test results. Solutions: Conduct tests according to standard operating procedures to ensure that air and condensate in the pipeline are fully vented before testing.   3) Inadequate Insulation of Steam Pipelines: Explanation: Damaged or insufficient insulation can cause steam to cool and produce condensate during transmission, reducing the dryness of the steam. Solutions: Check and repair the insulation layer of the steam pipeline to ensure its integrity and insulation effect.   The ZHICE-ELEC 50Ⅲ SQTK Steam Quality Testing Kit is designed for the quality testing of pure steam, ensuring sterilization efficiency.
  • What is Temperature Mapping: A Key to Environmental Consistency Jun 27, 2024
    What is Temperature Mapping: A Key to Environmental Consistency Temperature mapping, also referred to as thermal mapping, is a critical component of Good Manufacturing Practices (GMP). This systematic process enables companies to monitor and maintain the environmental conditions within a controlled space. Its primary goal is to minimize temperature and humidity variations, thereby ensuring a consistent environment in storage facilities, refrigeration units, or during transportation.     Differentiating Mapping from Monitoring While routine temperature monitoring is a standard practice, temperature mapping delves deeper by placing data loggers throughout a specific area over an extended period, typically 24 hours. This testing offers a detailed understanding of how temperature and humidity are distributed across the space. Analyzing the data allows companies to identify inconsistencies, which could be caused by frequent door openings, heat generated by machinery, or issues with HVAC systems, and make necessary adjustments to optimize the environment. After completing the temperature mapping study, regular temperature monitoring becomes essential. This ongoing process involves using a smaller set of data loggers to continuously observe the conditions where products are stored. In many industries, this step is required to ensure that environmental standards are consistently met.   Place Where Temperature Mapping is Applicable Temperature mapping is crucial in any setting where temperature or humidity levels can affect product quality. Even though some equipment includes built-in thermometers, these devices often measure temperature at a single, fixed point. For example, in a household refrigerator, items stored at the back are often colder than those near the door. Such temperature variations can lead to products being stored outside their ideal temperature range, rendering them unusable. This not only results in financial loss for manufacturers but can also pose significant risks to public health. For instance, if a pharmaceutical company only maps select areas of its warehouse, it might overlook temperature discrepancies in other sections. This oversight could result in distributing medications that are either ineffective or potentially harmful.     The Necessities of Temperature Mapping Incorporating temperature mapping into a company’s GMP guidelines is essential for identifying and correcting environmental inconsistencies, thereby ensuring proper storage conditions and regulatory compliance. When integrated into standard GMP practices, temperature mapping helps prevent product loss, safeguard financial investments, and enhance overall quality and public safety.   Suitable Devices A variety of different data loggers can be used for temperature mapping. There are a few things ZHICE take into consideration when we recommend using 298 series data logger for your mapping. Firstly, the difficulty for installation and communication. Simple USB download or WIFI communication version is suitable for small storage and for large warehouses, Zigbee version is recommended for stable signals and wider cover range. Secondly, the battery life. 298 series applies low power consumption design for long term testing over 24hours. It is common the batteries need to be changed after one year use (of course, the battery life depends on the usage environment and frequencies). Lastly, the data. Our software is 21CFR Part 11 ready and saves your time in statistics. Also, there are other logger choices for refrigerators, aerospace industries and other scenarios.   For more information, please chat with our friendly team real time online or email us at info@zhice-elec.com.  
Subscribe our newsletter

Please Read On, Stay Posted, Subscribe, And We Welcome You To Tell Us What You Think.

submit
Hefei Zhice Electronics Co., Ltd., established in 2003, is a high-tech enterprise and a provincial-level "specialized, specialized and innovative" enterprise. The company is located in the Science and Technology Industrial Park of the National High-tech Industrial Development Zone in Hefei City,
Contact Us

Copyright @ 2025 Hefei Zhice Electronics Co., Ltd.. All Rights Reserved. Sitemap / Blog / XML / Privacy Policy Network Supported

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
submit

Home

Products

WhatsApp

contact